FLAT WALL INSTALLATIONS
| 
CORNER INSTALLATIONS
(SIDE DOOR DISABLED)
| 
FIREPLACE HEARTH INSTALLATIONS
|
A: STOVE TO BACKWALL:
SINGLE-WALL STOVEPIPE: 18"
DOUBLE-WALL STOVEPIPE: 16"
| G: STOVE TO CORNER WALLS:
SINGLE-WALL STOVEPIPE: 13"
DOUBLE-WALL STOVEPIPE: 12"
| M: HEARTH TO OVERHEAD COMBUSTIBLES:
TRIM (UP TO 1" DEEP): 38-1/2"
MANTEL (1" - 8" DEEP): 77-1/2"
|
B: STOVE TO SIDEWALL:
LEFT (SOLID) SIDE: 12"
RIGHT SIDE, DOOR OPENABLE: 18"
RIGHT SIDE, DOOR DISABLED: 18"
| H: CENTERLINE PIPE TO WALLS:
SINGLE-WALL STOVEPIPE: 23-1/2"
DOUBLE-WALL STOVEPIPE: 22-1/2"
| N: MINIMUM HEARTH DEPTH, MEASURED
FROM FIREPLACE OPENING, COUNTING
EXTENSION IF NEEDED: 39"
|
C: CENTER OF PIPE TO BACKWALL:
SINGLE-WALL STOVEPIPE: 19-1/2"
DOUBLE-WALL STOVEPIPE: 17-1/2"
| I: CORNER TO FRONT LOP:
SINGLE-WALL STOVEPIPE: 66"
DOUBLE-WALL STOVEPIPE: 65"
| O: LINER SIZE REQUIRED: 6"
P: MINIMUM OPENING HEIGHT: 32-1/2"
|
D: CENTER OF PIPE TO SIDEWALL:
LEFT (SOLID) SIDE: 27"
RIGHT SIDE, DOOR OPENABLE: 63"
RIGHT SIDE, DOOR DISABLED: 27"
| J: CORNER TO EDGE OF HEARTH:
SINGLE-WALL STOVEPIPE: 60"
DOUBLE-WALL STOVEPIPE: 59"
|
|
E: MINIMUM HEARTH WIDTH:
SIDE DOOR OPENABLE: 48"
SIDE DOOR DISABLED: 36"
| L: WIDTH OF FRONT LOP: 40-1/4"
|
|
F: WALL TO FRONT OF HEARTH:
SINGLE-WALL STOVEPIPE: 53"
DOUBLE-WALL STOVEPIPE: 51"
| COMBUSTIBLE ALCOVE DIMENSIONS
W/SIDE DOOR DISABLED:
MINIMUM 58" WIDE X 77-1/2" TALL
MAXIMUM 38" DEEP
|
|