STOVE MODEL: HEARTHSTONE STERLING HT DIRECT VENT GAS STOVE STOVE DIMENSIONS: 29-1/2" WIDE X 21" DEEP X 27-1/8" TALL
EXHAUST PIPE USED (HORIZONTAL INSTALLS): 5" ID X 8" OD COAXIAL PIPE EXHAUST PIPE USED (VERTICAL INSTALLS): 4" ID X 6 5/8" OD COAXIAL PIPE
MINIMUM HEARTH (FLOOR PROTECTION): 30"W X 21"D (FOOTPRINT OF STOVE
VENTING OPTIONS: VERTICAL VENT: STRAIGHT UP (MAXIMUM 27 FT.) THROUGH A ROOF FLASHING TO 6 5/8" ROUND CAP HORIZONTAL VENT: STRAIGHT BACK (NO VISIBLE PIPE) TO 16" SQUARE x 6 3/4"D HORIZONTAL CAP THROUGH FIREPLACE: ADAPT TO 3"/3" CO-LINEAR FLEX PIPE THRU FIREBOX TO TOP SEALER PLATE. (MAXIMUM HEIGHT 30 FT.)
FLAT BACKWALL CORNER VERTICAL VENT HORIZONTAL VENT
FLAT WALL INSTALLATIONS | CORNER INSTALLATIONS |
A: STOVE TO BACKWALL IF VERTICAL VENTED.... 5-3/16" IF HORIZONTAL VENTED....... 2" | G: STOVE CORNERS TO CORNER WALLS...... 3" |
B: STOVE TO SIDEWALL.......... 4" | H: CENTERLINE OF VERTICAL PIPE TO CORNER WALLS................. 13.5" |
C: CENTERLINE OF VERTICAL PIPE TO BACKWALL........... 5-3/16" | I: CORNER TO CENTERLINE OF PIPE...... 19" TO FRONT OF WINDOW................ 40" |
D: CENTERLINE OF VERTICAL PIPE TO SIDEWALL........... 18-3/4" | M: FLOOR TO CENTERLINE OF EXHAUST PIPE IF HORIZONTAL VENTED.......... 21-1/2" |
E: BACKWALL TO FRONT OF DOOR: IF VERTICAL VENTED... 26-3/16" IF HORIZONTAL VENTED...... 23" | N: FLOOR TO TOP OF HORIZONTAL VENT CAP IF HORIZONTAL VENTED.......... 29-1/2" |
NOTE: HORIZONTAL VENT PIPE MUST RISE 1/4"/FT (NATURAL GAS), 1/2"/FT (LP GAS)
COMBUSTIBLE ALCOVE DIMENSIONS: MINIMUM 48"W X 54"T, MAXIMUM 20"D
TOP OF STOVE TO OVERHANGING COMBUSTIBLES: 14"
| When the Sterling HT is installed inside or in front of an existing fireplace, a Co-linear intake/exhaust system is used.First, the Vertical Vent Adapter must be attached to the stove. If the Sterling is to stand inside the fireplace as shown in Diagram A, a co-linear converter box is attached to the Adapter: if the Sterling is to stand outside the fireplace on the hearth as shown in Diagram B, a 90-degree elbow is used between the Adapter and the converter box. The converter box is then connected to a similar box at the flue top by two lengths of 3" aluminum flex, one for intake and one for exhaust. A coaxial rain cap completes the installation. With this system, combustion air is contained within the intake flex so it can't enter the room through the fireplace opening.Minimum Fireplace Opening Height:
|
|