The Chimney Sweep Online Fireplace, Woodstove, Gas Stove and Barbecue Shop
STOVE MODEL: HEARTHSTONE TUDOR DIRECT VENT GAS STOVE STOVE DIMENSIONS: 16" WIDE X 11" DEEP X 35" TALL CONNECTOR PIPE USED: 6 5/8" COAXIAL DIRECT VENT PIPE
NO HEARTH (FLOOR PROTECTION) NEEDED
VENTING OPTIONS: VERTICAL VENT: STRAIGHT UP THROUGH CEILING, ROOFING AND ROOF FLASHING TO A 6 5/8" ROUND CAP DIRECT VENT: STRAIGHT BACK THROUGH BACKWALL TO SQUARE 13 1/2"T x 13 1/2"W x 5 3/8"D CAP ANGLED IN CORNER: 45-DEGREE ELBOW THROUGH CORNER WALL TO SQUARE 13-1/2" X 13-1/2" CAP
FLAT BACKWALL CORNER DIRECT VENT
FLAT WALL INSTALLATIONS | CORNER INSTALLATIONS |
A: STOVE TO BACKWALL............... 0" | G: STOVE CORNERS TO CORNER WALLS IF DIRECT VENTED.................. 1" TO ALLOW FULL FOLDBACK OF DOORS... 3" IF VERTICAL VENTED............ 4-1/2" |
B: STOVE TO SIDEWALL............... 8" | H: CENTERLINE OF PIPE TO CORNER WALLS IF VERTICAL VENTED............. 4-5/8" |
C: CENTERLINE OF PIPE TO BACKWALL IF VERTICAL VENTED.......... 4-3/8" | I: CORNER TO CENTERLINE OF PIPE... 5-7/8" TO FRONT OF WINDOW................ 22" |
D: CENTERLINE OF PIPE TO SIDEWALL IF DIRECT VENTED............... 16" IF VERTICAL VENTED............. 16" | M: FLOOR TO CENTERLINE OF EXHAUST PIPE IF DIRECT VENTED.............. 28-1/2" |
E: BACKWALL TO FRONT OF DOOR IF DIRECT VENTED............... 12" IF VERTICAL VENTED............. 22" | N: FLOOR TO TOP OF HORIZONTAL VENT CAP IF DIRECT VENTED...............35-1/4" |
COMBUSTIBLE ALCOVE DIMENSIONS: MINIMUM 32"W X 40"T, MAXIMUM 36"D
MINIMUM FIREPLACE OPENING HEIGHT (FIREPLACE HEARTH INSTALLATIONS): 32"
TOP OF STOVE TO OVERHANGING COMBUSTIBLES: 16"
![]() | FIREPLACE HEARTH INSTALLATIONS:Determine the height of the chimney, and purchase enough 3" flexible aluminum liner to extend to the top of the chimney twice.Attach the two lengths of aluminum flex liner to the intake and exhaust ports on the top adapter box with pipe clamps or sheet metal screws and silicone sealant. Glue the top sealer plate to the chimney top with silicone sealant, and lower the two liner lengths through the opening. Anchor the top adapter box to the sealer plate with screws, and twist-lock the coaxial rain cap on top. Down below, use clamps or screws and silicone sealant to attach the two liner lengths to the bottom adapter box, which is used to connect the liners to a coaxial 90 degree elbow. The elbow then connects to the flue collar on the stove.If the stove is to stand inside the fireplace, connect the 90 degree elbow directly to the vent collar on the stove, as shown in the diagram at upper right. If the stove is to stand out on the hearth in front of the fireplace opening as shown at lower right, add a short length of pipe to clear the lintel bar, then install the 90 to attach the adapter box. |
|
|