STOVE MODEL: MENDOTA MEDALLION SDV-40 DIRECT VENT GAS STOVE STOVE DIMENSIONS: 29" WIDE X 18 3/4" DEEP X 29 1/4" TALL EXHAUST PIPE USED: 4"ID x 6 5/8" OD COAXIAL DIRECT VENT PIPE NO FLOOR PROTECTION REQUIRED ON WOOD FLOOR. HARD SURFACE REQUIRED ON VINYL, CARPET, ETC: 29"W x 18 5/8"D (SAME SIZE AS STOVE).
VENTING OPTIONS: VERTICAL VENT: STRAIGHT UP (MAXIMUM 35 FT.) THROUGH FLASHING TO 6 5/8" ROUND CAP DIRECT VENT: UP 24" (MINIMUM), 90 DEG. ELBOW THRU BACKWALL TO 13 1/2" SQUARE CAP
FLAT WALL INSTALLATIONS | CORNER INSTALLATIONS |
A: STOVE TO BACKWALL....... 2" | G: STOVE CORNERS TO WALLS........ 1-1/2" |
B: STOVE TO SIDEWALL...... 10" | H: CENTERLINE OF PIPE TO CORNER WALLS.............. 17-1/4" |
C: CENTERLINE OF PIPE TO BACKWALL......... 9-3/4" | I: DIAGONAL FROM CORNER TO CENTERLINE OF PIPE........ 24-1/4" TO FRONT OF VIEWING WINDOW... 35-3/8" |
D: CENTERLINE OF PIPE TO SIDEWALL........ 24-1/2" | J: FLOOR TO CENTERLINE OF PIPE...... 59" |
E: BACKWALL TO FRONT OF DOOR............ 20-3/4" | K: FLOOR TO TOP OF HORIZONTAL CAP............ 65-3/4" |
TOP OF STOVE TO OVERHANGING COMBUSTIBLES: 39"
COMBUSTIBLE ALCOVE DIMENSIONS: MINIMUM 49"W X 68 5/16"T, MAXIMUM 48"D