FLAT WALL INSTALLATIONS:
| CORNER INSTALLATIONS:
|
A: STOVE TO BACKWALL:
SINGLE-WALL STOVEPIPE........ 9"
DOUBLE-WALL STOVEPIPE........ 6"
MOBILE HOME.................. 7"
| G: STOVE TO CORNER WALLS:
SINGLE-WALL STOVEPIPE....... 4"
DOUBLE-WALL STOVEPIPE....... 4"
MOBILE HOME................. 5"
|
B: STOVE TO SIDEWALL:
SINGLE-WALL STOVEPIPE....... 12"
DOUBLE-WALL STOVEPIPE....... 12"
MOBILE HOME................. 14"
| H: CENTERLINE PIPE TO CORNER WALLS:
SINGLE-WALL STOVEPIPE.. 18-3/4"
DOUBLE-WALL STOVEPIPE.. 18-3/4"
MOBILE HOME............ 19-3/4"
|
C: CENTERLINE PIPE TO BACKWALL:
SINGLE-WALL STOVEPIPE... 17-1/2"
DOUBLE-WALL STOVEPIPE... 14-1/2"
MOBILE HOME............. 15-1/2"
| I: DIAGONAL FROM CORNER TO FRONT LOP:
SINGLE-WALL STOVEPIPE...... 59"
DOUBLE-WALL STOVEPIPE...... 59"
MOBILE HOME................ 61"
|
D: CENTERLINE PIPE TO SIDEWALL:
SINGLE-WALL STOVEPIPE... 24-3/4"
DOUBLE-WALL STOVEPIPE... 24-3/4"
MOBILE HOME............. 26-3/4"
| J: CORNER TO EDGE OF HEARTH:
SINGLE-WALL STOVEPIPE...... 56"
DOUBLE-WALL STOVEPIPE...... 56"
MOBILE HOME................ 57"
|
E: MINIMUM HEARTH WIDTH........ 38"
| L: WIDTH OF FRONT LOP..... 37-1/2"
|
F: BACKWALL TO FRONT OF HEARTH:
SINGLE-WALL STOVEPIPE....... 52"
DOUBLE-WALL STOVEPIPE....... 49"
MOBILE HOME................. 50"
| COMBUSTIBLE ALCOVE DIMENSIONS:
MINIMUM 55-1/2" Wide
MINIMUM 84" Tall
MAXIMUM 48" Deep
|