FLAT WALL INSTALLATIONS:
| CORNER INSTALLATIONS:
|
A: STOVE TO BACKWALL:
SINGLE-WALL STOVEPIPE.... 13.5"
DOUBLE-WALL STOVEPIPE..... 6.5"
MOBILE HOME............... 9.5"
ALCOVE................... 11.5"
| G: STOVE TO CORNER WALLS:
SINGLE-WALL STOVEPIPE... 12"
DOUBLE-WALL STOVEPIPE.... 5"
MOBILE HOME.............. 9"
|
B: STOVE TO SIDEWALL:
SINGLE-WALL STOVEPIPE.... 18"
DOUBLE-WALL STOVEPIPE.... 14"
MOBILE HOME.............. 16"
ALCOVE................... 16"
| H: CENTERLINE PIPE TO CORNER WALLS:
SINGLE-WALL STOVEPIPE... 25"
DOUBLE-WALL STOVEPIPE... 18"
MOBILE HOME............. 22"
|
C: CENTERLINE PIPE TO BACKWALL:
SINGLE-WALL STOVEPIPE.... 22"
DOUBLE-WALL STOVEPIPE.... 15"
MOBILE HOME.............. 18"
ALCOVE................... 20"
| I: DIAGONAL FROM CORNER TO FRONT LOP:
SINGLE-WALL STOVEPIPE... 67"
DOUBLE-WALL STOVEPIPE... 57"
MOBILE HOME............. 63"
|
D: CENTERLINE PIPE TO SIDEWALL:
SINGLE-WALL STOVEPIPE.... 30"
DOUBLE-WALL STOVEPIPE.... 26"
MOBILE HOME.............. 28"
ALCOVE................... 28"
| J: CORNER TO EDGE OF HEARTH:
SINGLE-WALL STOVEPIPE... 60"
DOUBLE-WALL STOVEPIPE... 53"
MOBILE HOME............. 57"
|
E: MINIMUM HEARTH WIDTH..... 34"
| L: WIDTH OF FRONT LOP...... 36"
|
F: BACKWALL TO FRONT OF HEARTH:
SINGLE-WALL STOVEPIPE... 54.5"
DOUBLE-WALL STOVEPIPE... 47.5"
MOBILE HOME............. 50.5"
ALCOVE.................. 52.5"
| COMBUSTIBLE ALCOVE DIMENSIONS:
MINIMUM 56" Wide
MINIMUM 90" Tall
MAXIMUM 48" Deep
|